X-ray Crystallography
X-ray Crystallography
Standard reconstruction benchmark — forward model perfectly known, no calibration needed. Score = 0.5 × clip((PSNR−15)/30, 0, 1) + 0.5 × SSIM
| # | Method | Score | PSNR (dB) | SSIM | Source | |
|---|---|---|---|---|---|---|
| 🥇 |
CrystFormer
CrystFormer Crystallographic transformer, 2024
32.5 dB
SSIM 0.915
Checkpoint unavailable
|
0.749 | 32.5 | 0.915 | ✓ Certified | Crystallographic transformer, 2024 |
| 🥈 |
DL-Phase
DL-Phase Jumper et al., 2021
30.5 dB
SSIM 0.880
Checkpoint unavailable
|
0.698 | 30.5 | 0.880 | ✓ Certified | Jumper et al., 2021 |
| 🥉 | SHELXD | 0.553 | 26.0 | 0.740 | ✓ Certified | Sheldrick, 2010 |
| 4 | Molecular Replacement | 0.412 | 22.0 | 0.590 | ✓ Certified | McCoy et al., 2007 |
Dataset: PWM Benchmark (4 algorithms)
Blind Reconstruction Challenge — forward model has unknown mismatch, must calibrate from data. Score = 0.4 × PSNR_norm + 0.4 × SSIM + 0.2 × (1 − ‖y − Ĥx̂‖/‖y‖)
| # | Method | Overall Score | Public PSNR / SSIM |
Dev PSNR / SSIM |
Hidden PSNR / SSIM |
Trust | Source |
|---|---|---|---|---|---|---|---|
| 🥇 |
CrystFormer + gradient
CrystFormer + gradient Crystallographic phasing transformer, 2024 Score 0.676
Correct & Reconstruct →
|
0.676 |
0.745
29.87 dB / 0.915
|
0.670
26.75 dB / 0.852
|
0.613
24.22 dB / 0.776
|
✓ Certified | Crystallographic phasing transformer, 2024 |
| 🥈 | DL-Phase + gradient | 0.630 |
0.710
27.99 dB / 0.881
|
0.618
24.37 dB / 0.781
|
0.563
22.47 dB / 0.710
|
✓ Certified | Jumper et al., Nature 2021 |
| 🥉 | SHELXD + gradient | 0.607 |
0.651
24.74 dB / 0.794
|
0.610
23.67 dB / 0.757
|
0.559
22.04 dB / 0.692
|
✓ Certified | Sheldrick, Acta Cryst. D 2010 |
| 4 |
Molecular Replacement + gradient
Molecular Replacement + gradient McCoy et al., J. Appl. Cryst. 2007 Score 0.455
Correct & Reconstruct →
|
0.455 |
0.497
19.24 dB / 0.562
|
0.449
17.9 dB / 0.495
|
0.418
17.47 dB / 0.474
|
✓ Certified | McCoy et al., J. Appl. Cryst. 2007 |
Complete score requires all 3 tiers (Public + Dev + Hidden).
Join the competition →Full-access development tier with all data visible.
What you get & how to use
What you get: Measurements (y), ideal forward operator (H), spec ranges, ground truth (x_true), and true mismatch spec.
How to use: Load HDF5 → compare reconstruction vs x_true → check consistency → iterate.
What to submit: Reconstructed signals (x_hat) and corrected spec as HDF5.
Public Leaderboard
| # | Method | Score | PSNR | SSIM |
|---|---|---|---|---|
| 1 | CrystFormer + gradient | 0.745 | 29.87 | 0.915 |
| 2 | DL-Phase + gradient | 0.710 | 27.99 | 0.881 |
| 3 | SHELXD + gradient | 0.651 | 24.74 | 0.794 |
| 4 | Molecular Replacement + gradient | 0.497 | 19.24 | 0.562 |
Spec Ranges (4 parameters)
| Parameter | Min | Max | Unit |
|---|---|---|---|
| crystal_orientation_error | -0.1 | 0.2 | deg |
| beam_divergence | 0.08 | 0.14 | mrad |
| absorption_correction | 0.98 | 1.04 | - |
| scale_factor | 0.99 | 1.02 | - |
Blind evaluation tier — no ground truth available.
What you get & how to use
What you get: Measurements (y), ideal forward operator (H), and spec ranges only.
How to use: Apply your pipeline from the Public tier. Use consistency as self-check.
What to submit: Reconstructed signals and corrected spec. Scored server-side.
Dev Leaderboard
| # | Method | Score | PSNR | SSIM |
|---|---|---|---|---|
| 1 | CrystFormer + gradient | 0.670 | 26.75 | 0.852 |
| 2 | DL-Phase + gradient | 0.618 | 24.37 | 0.781 |
| 3 | SHELXD + gradient | 0.610 | 23.67 | 0.757 |
| 4 | Molecular Replacement + gradient | 0.449 | 17.9 | 0.495 |
Spec Ranges (4 parameters)
| Parameter | Min | Max | Unit |
|---|---|---|---|
| crystal_orientation_error | -0.12 | 0.18 | deg |
| beam_divergence | 0.076 | 0.136 | mrad |
| absorption_correction | 0.976 | 1.036 | - |
| scale_factor | 0.988 | 1.018 | - |
Fully blind server-side evaluation — no data download.
What you get & how to use
What you get: No data downloadable. Algorithm runs server-side on hidden measurements.
How to use: Package algorithm as Docker container / Python script. Submit via link.
What to submit: Containerized algorithm accepting y + H, outputting x_hat + corrected spec.
Hidden Leaderboard
| # | Method | Score | PSNR | SSIM |
|---|---|---|---|---|
| 1 | CrystFormer + gradient | 0.613 | 24.22 | 0.776 |
| 2 | DL-Phase + gradient | 0.563 | 22.47 | 0.71 |
| 3 | SHELXD + gradient | 0.559 | 22.04 | 0.692 |
| 4 | Molecular Replacement + gradient | 0.418 | 17.47 | 0.474 |
Spec Ranges (4 parameters)
| Parameter | Min | Max | Unit |
|---|---|---|---|
| crystal_orientation_error | -0.07 | 0.23 | deg |
| beam_divergence | 0.086 | 0.146 | mrad |
| absorption_correction | 0.986 | 1.046 | - |
| scale_factor | 0.993 | 1.023 | - |
Blind Reconstruction Challenge
ChallengeGiven measurements with unknown mismatch and spec ranges (not exact params), reconstruct the original signal. A method must be evaluated on all three tiers for a complete score. Scored on a composite metric: 0.4 × PSNR_norm + 0.4 × SSIM + 0.2 × (1 − ‖y − Ĥx̂‖/‖y‖).
Measurements y, ideal forward model H, spec ranges
Reconstructed signal x̂
Spec DAG — Forward Model Pipeline
F → S → D
Mismatch Parameters
| Symbol | Parameter | Description | Nominal | Perturbed |
|---|---|---|---|---|
| c_o | crystal_orientation_error | Crystal orientation error (deg) | 0.0 | 0.1 |
| b_d | beam_divergence | Beam divergence (mrad) | 0.1 | 0.12 |
| a_c | absorption_correction | Absorption correction (-) | 1.0 | 1.02 |
| s_f | scale_factor | Scale factor (-) | 1.0 | 1.01 |
Credits System
Spec Primitives Reference (11 primitives)
Free-space or medium propagation kernel (Fresnel, Rayleigh-Sommerfeld).
Spatial or spatio-temporal amplitude modulation (coded aperture, SLM pattern).
Geometric projection operator (Radon transform, fan-beam, cone-beam).
Sampling in the Fourier / k-space domain (MRI, ptychography).
Shift-invariant convolution with a point-spread function (PSF).
Summation along a physical dimension (spectral, temporal, angular).
Sensor readout with gain g and noise model η (Gaussian, Poisson, mixed).
Patterned illumination (block, Hadamard, random) applied to the scene.
Spectral dispersion element (prism, grating) with shift α and aperture a.
Sample or gantry rotation (CT, electron tomography).
Spectral filter or monochromator selecting a wavelength band.